Screened flexible data transmission cables with pvc insulation and sheath, individually screened twisted pair and pvc inner sheath over each screened pair, 300/500V
Applications
Data transmission cable, control and connecting cable predominantly for transmission of analog and digital signals in process controlled facilities in measurement and control technology for lossless transmission of data and signals, with rated voltage 300/500V .For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. The copper braided screening prevents electrical and magnetic interference of the control cable with the environment.
Design
Conductor:
Stranded bare copper wires, class 5 по EN 60228
(except 0.34 mm2: 7 x 0.25 mm)
Insulation:
PVC Type TI2 to EN 50 363-3
Shore A: 88±3
Core identification:
Colour code to DIN 47100 with colour repetition for number of conductors over 44.
Construction:From cross section 0.14 mm2 up to 0.75 mm2
Assembly:2 cores twisted to pairs polyester foil on each pair.
Screen - on each pair:
Ttinned copper braiding on each pair (85 ± 5) % or another by agreement.
Inner sheath - on each pair:PVC Type TM2 to ЕN 50 363-4-1
Assembly:Pairs in concentric layers.
Separating foil:Polyester foil with a suitable thickness and overlapping.
Screen:Braided screening made of tinned copper wire,
coverage approx. 85 ± 5 % or another by agreement.
Drain wire under the braid by agreement.
Outer sheath:
PVC Type TM2 to ЕN 50 363-4-1
Shore A: 77 ± 3
Colour RAL 7001, RAL 7032 or another by agreement
Electrical data
Working voltage Uo/U:
for 0.14 mm2:
max 350 V
over 0.14 mm2:
max 500 V
Test voltage on finished cable a.c, 50 Hz:
for 0.14 mm2:
1200 V
over 0.14 mm2:
1500 V
Specific insulation resistance at 20°C: > 20 МΩ.km
Operating conditions
Minimum bending radius:
Flexing installation:
15 x cable diameter
Fixed installation:
6 x cable diameter
Working temperature:
Fixed installation:
-40°C up to +80°C
Flexing installation:
от -5°C up to +70°C
Flame behaviour: according to EN 60 332-1-2
CPR: Eca
According to standard:VDE 0812
Cable constructional data
Number and nominal cross sectionl of conductors
xx X 2 X [mm2]
Overall diameter of cable [mm]
2 X 2 X 0.14
8.60 ± 0.30
3 X 2 X 0.14
9.50 ± 0.30
5 X 2 X 0.14
11.90 ± 0.40
2 X 2 X 0.25
9.90 ± 0.30
3 X 2 X 0.25
10.40 ± 0.40
4 X 2 X 0.25
12.00 ± 0.40
5 X 2 X 0.25
12.70 ± 0.40
6 X 2 X 0.25
13.80 ± 0.40
12 X 2 X 0.25
18.70 ± 0.50
16 X 2 X 0.25
20.70 ± 0.50
2 X 2 X 0.34
11.40 ± 0.40
3 X 2 X 0.34
12.20 ± 0.40
4 X 2 X 0.34
13.70 ± 0.40
6 X 2 X 0.34
16.20 ± 0.50
2 X 2 X 0.50
12.30 ± 0.40
3 X 2 X 0.50
14.60 ± 0.40
4 X 2 X 0.50
16.10 ± 0.50
6 X 2 X 0.50
17.70 ± 0.50
12 X 2 X 0.50
23.30 ± 0.60
2 X 2 X 0.75
14.60 ± 0.40
Note: Cables with another number of conductors may be produced by agreement.